Good User Reputation for Graphic LCD Display Module for Malta Manufacturers

Short Description:

Sinda Display Technology Co., Ltd. is one of the best China Graphic LCD display  manufacturers and suppliers. We can custom graphic LCD display exactly according to your request and provide sample for quality evaluation in 2 weeks. Now we are provide graphic LCD display for  instrument like digital panel meter,multimunction meter, POS machines, LGP Dispenser, Fuel Dispenser, Oil Dispenser, Gas Dispenser, Flow Meter, KWH Meter, Energy Meter, Water Meter, Gas Meter, Smart Meter, Clock & Wat...


Product Detail

Product Tags

Related Video

Feedback (2)

, , ,
Good User Reputation for Graphic LCD Display Module for Malta Manufacturers Detail:

Sinda Display Technology Co., Ltd. is one of the best China Graphic LCD display  manufacturers and suppliers. We can custom graphic LCD display exactly according to your request and provide sample for quality evaluation in 2 weeks. Now we are provide graphic LCD display for  instrument like digital panel meter,multimunction meter, POS machines, LGP Dispenser, Fuel Dispenser, Oil Dispenser, Gas Dispenser, Flow Meter, KWH Meter, Energy Meter, Water Meter, Gas Meter, Smart Meter, Clock & Watch, Telecommunications device, Home Appliance, Industrial Controller, Car Audio, Color Display Systems and the other industries, Measurement device, UPS, Solar Inverter.

Model No Size(mm) VA(mm) Drive IC Interface
122×32 SDGB12232-04 80.00 × 36.00 × 12.80 60.00 × 18.00 SBN1661 or Eqv.  Parallel
128 × 64 SDGB12864-01 54.00 × 50.00 × 7.50 43.60 × 29.00 AIP31107 or Eqv. Parallel
SDGB12864-05 78.00 × 70.00 × 12.50 62.00 × 44.00 AIP31107 or Eqv. Parallel
SDGB12864-03 78.00 × 70.00 × 12.50 62.00 × 44.00 RA6963 or Eqv. Parallel
SDGB12864-04 93.00 × 70.00 × 12.50 72.00 × 40.00 AIP31020 or Eqv. SPI&Parallel
SDGB12864-02 93.00 × 70.00 × 12.50 72.00 × 40.00 AIP31107 or Eqv Parallel
SDGB12864-06 93.00 × 70.00 × 12.50 72.00 × 40.00 AR6963 or Eqv. Parallel
SDGB12864-07 100.00 × 60.50 × 12.00 70.30 × 38.50 AIP31107 or Eqv. Parallel
128 x 128 SDGB128128-01 92.00 × 106.00 × 12.50 73.00 × 73.00 SAP1024B or Eqv. Parallel
160 × 128 SDGB160128-01 129.00 × 102.00 × 12.00 101.00 × 82.00 RA6963 or Eqv. Parallel
SDGB160128-02 129.00 × 104.50 × 12.00 101.00 × 82.00 SAP1024B or Eqv. Parallel
SDGB160128-03 143.00 × 105.00 × 15.50 101.00 × 82.00 RA6963 or Eqv. Parallel
192 × 64 SDGB19264-01 100.00 × 60.00 × 11.30 84.00 × 31.00 AIP31107 or Eqv. Parallel
SDGB19264-02 130.00 × 65.00 × 13.50 104.00 × 39.00 AIP31107 or Eqv. Parallel
SDGB19264-03 130.00 × 65.00 × 13.50 104.00 × 39.00 ST7920 or Eqv. SPI&Parallel
SDGB24064-02 180.00 × 65.00 × 12.00 132.00 × 39.00 T6963C or Eqv. Parallel
240 × 128 SDGB240128-01 144.00 × 104.00 × 14.00 114.00 × 64.00 RA6963C or Eqv. Parallel
SDGB240128-03 154.00 × 84.00 × 12.00 114.00 × 64.00 RA6963C or Eqv. Parallel
320 × 240 SDGB320240-01 160.00 × 109.00 × 11.00 122.00 × 92.00 RA8835 or Eqv. Parallel
SDGB320240-02 139.00 × 100.00 × 12.50 103.00 × 79.00 RA8835 or Eqv. Parallel
SDGB320240-03 139.00 × 100.00 × 12.50 103.00 × 79.00 RA8835 or Eqv. Parallel
SDGB320240-04 160.00 × 109.00 × 12.00 122.00 × 92.00 RA8835 or Eqv. Parallel

Product detail pictures:

Good User Reputation for Graphic LCD Display Module for Malta Manufacturers detail pictures


Related Product Guide:

Good User Reputation for Graphic LCD Display Module for Malta Manufacturers, The product will supply to all over the world, such as: , , ,


  • Net Metering has not yet been implemented in Iligan City…Im not afraid to show off this video since we dont tamper the electric meters…and by knowledge we have known that GE-i210 default configuration is RECEIVED+DELIVERED = POSITIVE ACCUMULATION according to the service manual. And there is already a Republic Act governing this grid tie inverters what was known to be RA 9513 known as Renewable Energy Act of 2008 enabling net metering program for residential establishments….

    The Video is a test of how the electric meter reacts to the ENERGY BEING Produced by the Grid Tie inverter and fed to the existing system….as what we can clearly see that the electric meter will visibly reverse its direction if the Produced power is greater than the consumption…Always note that the Digital Meters of general Electric uses the word RECEIVED and DELIVERED….Normally all electric meters will have the indication DELIVERED except for the instances of using GRID TIE INVERTERS in which it will change to RECEIVED….

    This video portrays a meter in which it is in its original form and not being tampered. We only generate POWER from the SUN and being inverted to usable power and synchronized in the main system as to portray 2 generators being synchronized to have load sharing principle. The main generator is the DISTRIBUTION UTILITY and the 2nd generator is the GRID TIE inverter…Synching is done automatically and as per the features of the GTI, the product is fail safe and safety to use…No user intervention. Just plug it in the outlet and everything is done according to its design…Our solar panel are 2 pcs. 120 watts PolyCrystalline and 2 pcs 80 watts monocrystalline. The Maximum power ever recorded in our configuration is achieving 210 Watts of Power being indicated by the DIGITAL WATT-METER.

    Our problem now lies with the default configuration of the GE Electric Meter in which the service manual states that the default setting is RECIEVED+DELIVERED = POSITIVE ACCUMULATION….So by now, if we are producing more energy than what was needed, it will be a positive register to the meter…Even if the indication is RECEIVED, then still we have to pay for it because it will register in the meter…so the only hope that we have now is to make the excess power/energy as little as possible so that what we are paying for is as little as it should be. The idea is to always make the Meter Register to ZERO….by that means, the electric meter is not registering any power used since it indicates ZERO! Which means that the consumption and the production is just equal….But that is only idealistic…The truth is to have an excess as little as possible so that the Meter will only register that little energy being produced despite of heavy LOADS in the house….

    The words that i have expressed are only my interpretation…This is only according to my experience and mixed with Engineering Principles since I am an Electrical engineer, a product of St. Peter’s College.

    The video’s sole purpose is for exhibition only and not for Defying ACTS…
    I challenge all the ELECTRICAL ENGINEERS in IIEE-IBC Chapter (Iligan Bay Chapter) to implement as fast as possible the RA 9513 NET METERING SCHEME so that energy crisis will be addressed and i believed that if the population has this Grid tie Inverters installed in their homes, the GENERATING COMPANY would lessen the operating cost since the DEMAND is quite lower due to the contribution of the energy each entity will produce. I challenge the IIEE Board Members to seriously take into account the benefits of having grid tie inverters and having NET METERING ENABLED in the D.U. I challenge also the SENATE to make a LAW that would enable the PEOPLE to LOAN from PAG-IBIG a grid tie inverter and Solar Panel LOAN so that many more people will install this kind of device and enjoy FREE ENERGY from the SUN without using any storage batteries.
    I challenge also the DOE (Department of Energy) to make the default configuration of the G.E. electric meter to DELIVERED – RECIEVED = POSITIVE ACCUMULATION in areas where NET METERING is not yet implemented so that whatever the energy produced by the GTI would not be in vain and not wasted since the DIGITAL ELECTRIC METER is registering RECIEVED or Negative values.
    Our Country Philippines is suffering from energy crisis. This is the answer to the problem. Enable the people to have these installed in their houses and the crisis will loosen its grip. I have already been in foreign countries and as what I have observed, america or the american people were using the GRID TIE TECHNOLOGY. As i wandered in the streets of the Federal States, i could see numerous roofs have solar panels. It concluded into my mind that no wonder, the west is enjoying free energy from the SUN. And while i was in EUROPEAN UNION countries, I saw also numerous houses with solar panels in their roof …These countries are Rich and they dont seem to have a crisis in the energy sector.



    https://github.com/jchango/GLCD-PIC-C-and-more../tree/master


    5 Stars By from -

    5 Stars By from -

    Related Products

    WhatsApp Online Chat !